Overview
My engine turns a short questionnaire and an address into a ranked recommendation by simulating one year of a home's energy flows, half-hour by half-hour, for every sensible combination of equipment, tariff and behaviour, then projecting each one forward over the years the customer expects to stay.
The core unit is a modelled year: 365 days × 48 half-hours = 17,520 intervals, starting twelve months ago so that it lines up with twelve months of real half-hourly wholesale-linked prices and the real weather of the same months (currently November 2025 to October 2026). In each interval the engine models the outdoor temperature and sunshine near the home, how much electricity the home needs, how much heat it needs, what any solar panels generate, what a battery does, and what each kilowatt-hour costs to buy or earns when sold.
One run follows six steps:
- Describe the home. Form answers are combined with roof geometry and the home's Energy Performance Certificate (EPC).
- Synthesise the year. Half-hourly profiles are built for household electricity, space heating, hot water, electric-vehicle charging and solar generation, with heating, heat pump efficiency and solar following the real weather near the home.
- Enumerate scenarios. The home as it is today (current equipment, tariff and habits) is set as the baseline, then every combination of solar size, battery size and heat pump is crossed with every tariff pair the home could have and two effort levels representing user interventions.
- Simulate each scenario. The battery is dispatched, grid imports and exports are priced, and the first-year saving against the baseline is found.
- Project forward. Each saving is extended year by year with energy-price projections and equipment ageing, giving net benefit and payback.
- Pick and qualify. The option with the largest net benefit is chosen in each budget band at each effort level, and low/high ranges are worked out.
Google Solar, the EPC and the local weather shape the home model; Octopus prices decide which tariffs each scenario can use; DESNZ projections enter to project savings forward.
A typical home produces 80 equipment combinations (up to 10 solar sizes × 4 battery sizes × 2), each run once at Effort Level 0 and once per eligible tariff at Level 1, so several hundred simulated years per request. A full run takes about 6 to 13 seconds.
Two effort levels describe how the household behaves after installation:
- Level 0, install and forget: the current tariff is kept, the battery simply stores surplus solar, and appliances, car charging and hot water run when they always did.
- Level 1, set up once: the home may switch tariff, the car charges in the cheapest hours, hot water heats on a fixed timer, a new heat pump may pre-heat before the evening peak, and the battery follows prices (including selling to the grid when it pays).
Inputs and data sources
The engine draws on four live data services, a year of weather data held with the engine, and a set of researched reference files; only the customer's form answers are stored, with roof and certificate data looked up fresh on every run.
| Source | What it provides | How the engine uses it |
|---|---|---|
| Customer form | People in the home, daytime occupancy, heating fuel and boiler age, existing solar/battery/heat pump, EV mileage and charging habits, current import and export tariff, ownership, budget, planned stay, optional oil/LPG spend | Household profile, baseline, eligibility for tariffs and grants, ranking horizon |
| Google Places API | The address's coordinates | Latitude and longitude, each rounded to 0.1° (about 11 km north–south and 7 km east–west) before they reach the engine: the sun's path and the nearest weather grid point |
| Google Solar API (building insights) | Each roof segment's area, pitch, compass direction and median annual sunshine hours; panel size and the largest array Google can lay out | Usable roof faces, their capacity and their yield per kWp |
| EPC register (MHCLG energy performance data service) | Property type, floor area, ground-floor footprint, rating, modelled space-heating and hot-water demand | Heat demand; roof size for semi-detached and terraced homes |
| Octopus Energy public API | Electricity region from postcode; unit rates and standing charges for each product; twelve months of half-hourly Agile import and export prices | Every tariff's half-hourly import and export price series, and gas prices |
| ERA5 reanalysis (Copernicus Climate Change Service) | Hourly outdoor temperature and sunshine (actual and clear-sky) on a grid about 28 km apart across Great Britain, for the modelled year | Space heating timing, heat pump efficiency and cloud for the grid point nearest the home |
| DESNZ Green Book supplementary guidance | Domestic retail price projections to 2050 (electricity, gas, heating oil; low, central, high) | Year-by-year price index for future savings |
| Reference files (researched) | Installed costs, grants, VAT, heat pump efficiency, equipment fade, future equipment price falls, oil and LPG prices, virtual power plant payments | Costs, grants and assumptions with low/central/high values |
Each reference value carries its source, a status (researched, judgement or placeholder) and a last-checked date to ensure that all are kept up to date.
Where a live source is missing, the engine falls back in a fixed order. Heat demand comes from the EPC's modelled figures, else EPC floor area × a heat intensity for the build period, else a table by number of bedrooms. Roof data comes from Google, else a typical south-facing roof at 900 kWh per kWp. The electricity region comes from the postcode, else a default region. Weather and the sun's path come from the home's rounded coordinates, else the centre of England and Wales (52.5°N, 1.9°W).
Household electricity demand
Appliance and lighting use is synthesised as a smooth daily shape with a seasonal swing and day-to-day noise, then scaled so the year adds up to a total set by the number of occupants.
The annual total is 1,800, 2,500, 2,900, 3,300 or 3,800 kWh for one to five or more people. Within each day the shape is a baseline plus three Gaussian bumps, at 07:30, 18:30 and (if someone is home in the day) 13:00:
Here h is the UK clock hour and w is 0.5, 0.375, 0.25 or 0 for someone being at home always, often, sometimes or rarely. A seasonal term peaks in mid-January:
where d is the day of the year. Half-hourly use is then
so that winter use is about 25% above average and summer use 25% below. The random term is seeded, so every run of the same home gives the same year.
Electric vehicle charging
A car's daily energy at home is
with efficiency η of 3.5 miles per kWh by default (grid side, so charging losses are included) and f equal to 1 with a home charger and 0 without. The car is assumed plugged in from 19:00 to 07:00 on a 7 kW charger, so at most 3.5 kWh can flow in any half-hour.
At Level 0 charging starts at plug-in and runs until the day's energy is delivered. At Level 1 (or if the customer already schedules charging), the same energy is placed into the cheapest half-hours of that night's window: slots are sorted by import price and filled to 3.5 kWh each until the energy is used up. The same load-shifting routine, which keeps each session's total and only moves its timing, is reused elsewhere for other flexible loads.
Heat demand, boilers and heat pumps
Heat is modelled as heat delivered to the home (space heating plus hot water), independent of what produces it, so that a boiler and a heat pump can be compared on the same demand.
Annual heat demand
With an EPC, space heating starts from the certificate's modelled demand, corrected for the well-documented tendency of EPCs to overstate consumption in less efficient homes. Hot water is taken as the certificate states.
| EPC band | A/B | C | D | E | F/G | Unknown |
|---|---|---|---|---|---|---|
| Space-heating factor | 1.00 | 0.92 | 0.81 | 0.65 | 0.52 | 0.84 |
The banded factors come from Few et al. (2023), who compared metered consumption with EPC predictions for UK homes (C and F/G as the paper states them; D and E worked out from its Table 2 and Figure 5), and the unknown-band factor matches the 16% average gap in DESNZ's EPC accuracy research (2026). Without an EPC demand figure, space heating is floor area × an intensity of 40 to 150 kWh/m² by build period, else a table by bedrooms (4,000 to 13,500 kWh a year).
For oil and LPG homes, which have no meter, an optional annual spend is converted into delivered heat and blended with the estimate:
where c is the fuel's energy per litre (10.35 kWh for kerosene, 7.08 for LPG). The 80/20 weighting reflects that tank deliveries rarely line up with a 12-month window.
Half-hourly shape
Space heating follows the outdoor temperature near the home. Each day's need is proportional to its heating degree days: how far the day's mean outdoor temperature falls below a base temperature of 15.5°C (the point at which a typical home's internal gains keep it warm). A whole day is used rather than each half-hour because a house holds its heat: a cold night shows up in the next morning's heating, not in that half-hour. Within the day the heat is shaped by morning and evening peaks at 07:00 and 18:00:
where is the UK clock day that half-hour falls in.
So a cold snap in March gets more heat than a mild week in January, and a warm spell switches the heating off whatever the date. The annual total still comes from the EPC (or the fallbacks above); the weather decides only when it is used. Hot water runs all year, about 10% higher in winter:
Each is normalised to its annual total.
Boilers
Fuel burned is heat delivered divided by seasonal efficiency, which falls with boiler age: 0.88 under 10 years, 0.84 at 10 to 20 years, 0.72 over 20 years (pre-condensing), 0.82 if unknown. Gas is priced at the Octopus Flexible unit rate plus standing charge; oil and LPG at a UK average price per litre. Replacing a gas boiler with a heat pump is assumed to remove the gas standing charge.
Heat pumps
A heat pump's efficiency depends on the outdoor temperature: it falls in cold weather, and it is lower for hot water, which needs a higher flow temperature. The engine gives each half-hour a coefficient of performance (COP) from the outdoor temperature, using the shape of Octopus's published Cosy fleet data (the median COP of its heat pumps at each outdoor temperature from −5°C to 20°C, November 2025 to November 2026):
where c(T) is the fleet's median COP at temperature T, read linearly between whole degrees (2.72 at −5°C, 3.11 at 0°C, 4.24 at 10°C, peaking near 4.4 at 13°C). Below −5°C the slope from −5 to 0°C carries on, down to a floor of 1.5; above 20°C it holds the 20°C value. Hot water runs at 92% of the heating figure at the same temperature, the ratio of the fleet's summer hot-water-only results to its mild-weather heating results.
The fleet is a selected group of recent installations, so the curve sets the shape, and a single scale factor a sets the level. It is chosen once so that a reference home (three bedrooms at the centre of England and Wales) has a seasonal performance factor (SPF, total heat out ÷ total electricity in) of 3.5 centrally, with 2.8 (the median from the government-funded Electrification of Heat trial) and 3.9 (close to the Cosy fleet's own figure) as the low and high cases:
On the modelled year's weather the reference home would reach 3.77 on the fleet's own curve (the fleet as a whole reaches 3.91), so a is about 0.93 centrally, 0.74 for the low case and 1.04 for the high case. It is worked out afresh from the weather on each run, so it moves when the modelled year does.
Every other home uses the same a, so its own weather moves its SPF: for the same home, about 3.7 in Cornwall and 3.35 in Inverness against 3.5 near Birmingham. Direct electric heating is modelled at 1 kWh of electricity per kWh of heat.
Solar generation
Each usable roof face gets its own annual yield from Google's sunshine data and its own timing from its compass direction and pitch under the real weather; the faces' outputs are summed.
Usable faces and capacity
A roof segment counts as usable if it is at least 8 m², no steeper than 60°, and receives at least 75% of the sunniest segment's sunshine. At most the three sunniest faces are used, since more makes scaffolding and wiring impractical. Capacity per face is
with 80% of the face assumed usable around edges, vents and windows, and Google's panel dimensions (else 400 W on 1.96 m²). For detached houses and bungalows the total is capped at Google's own maximum layout. Google often treats a terraced row as one building, so for semi-detached and terraced homes the front face is derived from the EPC footprint instead,
for a dual-pitch roof at pitch θ, with the back face mirrored and given the sunshine of the nearest Google segment facing that way. Panels fill the sunniest face first.
Annual yield
Yield per kWp for a face is
where H is the median annual sunshine hours for that segment (which already reflects tilt, orientation and local shading). The 0.95 factor was calibrated on a real 4.7 kWp east-facing array that produced 0.95 to 0.99 of its Google sunshine figure in 2025 and 2026. Without roof data, a south-facing 900 kWh per kWp is used.
Half-hourly shape
The timing follows the sun's position at the house's location, rounded to protect privacy, and the real sunshine at the nearest weather grid point. The sun's height and direction come from the standard formulas for its declination and hour angle,
where is the hour in UTC, λ and the home's latitude and longitude (east positive), so solar noon comes about 4 minutes later for each degree west, and the equation of time in minutes, which moves solar noon by up to about a quarter of an hour through the year. Both coordinates are rounded to 0.1° (52.5°N, 1.9°W if they aren't known).
The weather gives the sunshine on flat ground, (each hour's mean, spread over its two half-hours by the sun's height). How clear the sky is, , is that sunshine against what arrives at the top of the atmosphere, and it sets the share that is diffuse light from the whole sky rather than direct from the sun (the Erbs correlation):
where allows for the Earth's changing distance from the sun. The light on a face tilted at pitch β and facing α is then the direct light by the angle θ between the face and the sun, the diffuse light from the part of the sky the face sees, and a little reflected off the ground (20%):
with direct light left out while the sun is below about 4°. Panels lose about 0.4% of their output per degree above 25°C, and run hotter than the air in strong sun:
So an east-facing roof peaks in the morning, a steep south roof does relatively better in winter, and a cloudy day brings little output whatever the direction. The year is then normalised to the face's annual output, so the weather and the roof's geometry decide when the energy arrives and Google's data decides how much:
Checked against the real 4.7 kWp east-facing array above for November 2025 to October 2026, the modelled month-by-month pattern was within 5% from March to September and 15 to 23% high in the four darkest months, an average miss of 15 kWh a month (the previous, synthetic model's was 48).
A dull, cold week therefore now brings low solar output and high heating demand together, as it does in reality, which matters most for batteries and heat pumps.
Inverter sizing and clipping
A new array's inverter is sized at kWp ÷ 1.3 (a typical DC-to-AC ratio), rounded up to a standard single-phase size of 3.6, 5, 6 or 8 kW. Output above the inverter rating in any half-hour is lost:
On test roofs clipping costs under 0.5% of annual output, because half-hourly peaks rarely exceed 0.85 kW per kWp.
The sizes compared are 0, 2, 3, 4, 5, 6, 8, 10 and 12 kWp, up to whatever the roof holds, plus the largest half-kWp size that fits.
Flexible heating at Level 1
At Level 1 the engine moves electric heating loads into cheaper hours with settings a household would configure once, never with day-by-day intervention.
Hot water on a timer
Where hot water is heated electrically (by a heat pump, or an immersion heater in an electrically heated home with a cylinder), it is reheated in two fixed two-hour blocks a day: one in 00:00 to 07:00 and one in 11:00 to 16:00. The start time of each block minimises the tariff's average price over the block at each clock half-hour across the year:
where W is the allowed window and is the mean import price at clock time c. Ties (for example on a flat tariff) go to the block centred on 03:00 or 13:00, the latter coinciding with peak solar. Water used between the overnight and midday blocks is reheated at midday; the rest is reheated overnight. Each block delivers at most 1.0 kWh per half-hour from a heat pump or 1.5 kWh from a 3 kW immersion, widening if needed. Annual energy is conserved.
Pre-heating
A new heat pump can bank heat in the building fabric ahead of the 16:00 to 19:00 peak. Half of each day's peak space heating moves into 13:00 to 16:00, with 10% extra heat to cover what the warmer house loses:
It is only considered where the boost hours are cheaper even after the penalty, that is where , which is true on Agile and Cosy but not on flat or overnight-only tariffs. Even then each scenario is costed both with and without pre-heating and the cheaper is kept, because a battery or solar may already cover the evening peak. An existing heat pump pre-heats only if the customer says its heating can follow a schedule.
Battery simulation
The battery is stepped through all 17,520 half-hours in sequence, with a simple rule at Level 0 and a day-ahead price plan at Level 1.
State and limits
Let n be demand minus solar in a half-hour, S the stored energy, C the usable capacity and P the power rating. Round-trip efficiency is 90%, split equally each way, and the energy that can move in one half-hour is capped by power:
The battery starts empty. P is the inverter's rating when the battery is fitted with new solar, otherwise 5 kW. Batteries are offered at 0, 5, 10 and 15 kWh.
Level 0: self-consumption
Surplus solar charges the battery and any remainder is exported; a shortfall is met from the battery first and the grid second:
where I and X are grid import and export.
Level 1: price-aware planning
Each day is planned with that day's known half-hourly prices (perfect foresight within the day, no solar forecast). The number of slots needed to fill the battery is
The k cheapest import slots are candidates for grid charging, and the k most valuable slots are candidates for discharging, where a stored kilowatt-hour is worth the higher of the import price it avoids and the export price it could earn, . A cheap and a dear slot are paired only if the spread beats the round-trip loss:
On days with profitable pairs, discharge is restricted to the paired dear slots, and grid-bought energy is held in a reserve for them rather than spent on the first demand that appears. The battery may also sell to the grid in a dear slot when
The 4p margin covers wear: about £270 per kWh of capacity spread over roughly 6,000 cycles is 4 to 5p for every kilowatt-hour passed through. Exports are not capped by the model; options with more than 3.68 kW of export capability carry a note that the network operator may need to approve the connection.
Virtual power plant income
At Level 1, any option with a battery is assumed to join Axle Energy's virtual power plant, which pays battery owners for discharging during grid stress events. The engine adds its guaranteed minimum of £120 a year (low and central) and £300 a year in the high case, without simulating individual events.
Tariffs and the annual bill
Every tariff is represented as an import and export pair: a half-hourly import price series, a half-hourly export price series and a daily standing charge, all for the home's own electricity region.
The region (one of the 14 distribution areas) comes from Octopus's grid-supply-point lookup for the postcode. Prices are then fetched from Octopus's public product API in one of two ways:
- Current rates repeated: for fixed-shape products (Flexible, Go, Cosy, Flux, Outgoing), today's rates by UK clock time are repeated across the modelled year.
- History replayed: for the half-hourly products (Agile import and Agile Outgoing export), the real prices of the past twelve months are replayed slot by slot, so the battery and load-shifting logic meet realistic day-to-day volatility.
| Product | Import shape | Eligibility in the model |
|---|---|---|
| Flexible Octopus (standard) | Single rate | Any home |
| Octopus Go | Cheap overnight window | EV with a home charger |
| Agile Octopus | Half-hourly, linked to wholesale prices | Any home |
| Cosy Octopus | Three cheap periods (04:00–07:00, 13:00–16:00, 22:00–00:00), 16:00–19:00 peak | Heat pump (existing or new) |
| Octopus Flux | Cheap 02:00–05:00, peak 16:00–19:00, import and export together | Solar and battery |
Export options are Outgoing Octopus (a flat rate) and Agile Outgoing (half-hourly), paired with each import product as Octopus's smart tariff terms allow; Flux carries its own export. With solar or a battery, Level 1 tries up to nine pairs. Without either, nothing is exported and only one pair is costed. A customer on the basic Smart Export Guarantee (4.1p) or no export tariff keeps that at Level 0, but neither is ever suggested as a switch.
The annual electricity cost of a scenario, in pounds, is
with import I, export X, import price p and export price q per half-hour (pence per kWh), and standing charge s (pence per day). The full running cost adds heating fuel:
The fuel term is zero once a heat pump is installed. The baseline uses the customer's current tariff; Level 0 scenarios keep it, and Level 1 scenarios may switch to any eligible pair. Because fixed-shape products repeat today's rates while Agile replays last year's prices, closely matched tariffs can swap places as prices move.
Costs, grants and the scenario search
Installed costs are built from component formulas with low, central and high values, so that a 6 kWp system costs more than a 4 kWp one in a realistic, non-linear way.
Solar
Low and central costs are a fixed amount (scaffolding, electrician's visit, a 5 kW inverter, paperwork) plus a price per kilowatt-peak:
with a = £1,500 and b = £620/kW in the low case (anchored to a real 7.2 kWp quote) and a = £2,500, b = £850/kW centrally (2026 consumer guide prices). The last term pays for an inverter above 5 kW, at £120 per extra kW plus an installer margin m of 0, 25 or 40%. The high case follows the government's solar cost statistics (mean installed cost from MCS registrations): £2,109/kW at 3.5 kWp and £1,651/kW at 5.5 kWp, interpolated linearly between and held flat outside.
Batteries
A battery fitted on its own, or onto existing panels, needs its own inverter and installation visit:
with cell cost £270 per kWh from UK retail prices, an £800 inverter, margin m of 0/25/40% and installation L of £500/£1,000/£2,000. Fitted alongside new panels it shares the solar inverter and visit:
with a hybrid inverter uplift U of £0/£300/£500 and add-on installation L' of £250/£500/£1,000.
Heat pumps, VAT and grants
An air source heat pump costs ~£9,000 - £15,000 installed. All prices exclude VAT, which is 0% on these installations until 31 March 2027 and 5% afterwards. Owner-occupiers replacing fossil or direct electric heating receive the Boiler Upgrade Scheme grant: £7,500, or £9,000 for oil and LPG homes installing before 1 April 2027. Shared owners are assumed not eligible, and renters are offered tariff and behaviour changes only.
The search
The engine enumerates every combination the home can take: solar sizes up to the roof limit, batteries of 0, 5, 10 and 15 kWh, and a heat pump or not, skipping anything already installed. Each runs once at Level 0 on the current tariff and once per eligible pair at Level 1. For each, the first-year saving is
The scenario then falls into a budget band by its net cost: under £5,000, £5,000 to £10,000, £10,000 to £15,000, or above. Intermediate results (usage profiles, solar profiles, hot water timers) are cached and reused across scenarios that share them, which, with the battery's half-hour loop compiled to machine code, keeps several hundred simulated years within a few seconds.
Future prices, equipment ageing and the ranking
The first-year saving is turned into a 50-year path in real terms (today's pounds, no discounting), and options are ranked on the total saving over the customer's planned stay minus what they pay.
Price paths
Each fuel follows DESNZ's domestic retail price projection from the Green Book supplementary guidance (October 2026 tables: electricity, gas and heating oil in real 2025 prices, including standing charges). The engine uses these only as an index relative to the install year :
so year one is always at today's prices. Years beyond 2050 hold the 2050 value. Imports, every export tariff and electricity standing charges follow the electricity index; gas follows gas; oil and LPG follow oil. The central paths fall in real terms between 2026 and 2046 by about 30% for electricity, 21% for gas and 7% for oil, mostly before 2030.
Equipment ageing
New panels lose output at a compounding rate (0.5% a year centrally) and new batteries lose usable capacity linearly at percentage points of their original size (2 points a year centrally). Existing equipment and heat pumps are not faded. Rather than re-simulate every year, the first-year run records what the new kit is worth that year:
and a faded year loses the faded share of each:
Treating value as proportional to size slightly overstates the loss for large systems, whose last kilowatt-hour is worth less than the average, so the approximation errs on the cautious side.
The saving path
With E and F the baseline (b) and scenario (s) electricity and fuel costs from the year-one run, the saving in year k is
with the virtual power plant payment held flat in real terms.
Net benefit and payback
The ranking horizon N is 4, 8 or 15 years for a planned stay of under 5, 5 to 10, or over 10 years. Net benefit is
and the recommendation in each budget band, at each effort level, is the scenario with the largest NB. Payback is the first point at which the cumulative saving covers the net cost, interpolated within the year:
Payback is shown but not ranked on. The dashboard compares it with the stay as a band (0–5, 5–10 or 10–20 years). If a band's best option does not pay back by the top of the stay band, it is still shown as the least-bad choice, with a note naming the smallest higher budget whose pick would.
Monthly figures and a loan example
Most households pay for energy by a flat monthly direct debit, so the dashboard leads with monthly figures: the first year's saving divided by 12, with the average over the stay, , underneath.
Next to it is an illustrative loan from the government's Warm Homes Loan Scheme for the net cost: a representative example, not an offer. The rate is 3% a year, the government's own example of a lender's normal rate less the scheme's reduction, and the term is the ranking horizon N kept between the scheme's 3-year minimum and 10 years. The fixed monthly repayment is the standard annuity formula:
Repayments are fixed in pounds while savings are in today's money; I leave the repayments at their face value rather than letting inflation shrink them, which errs on the cautious side. The loan view of the chart starts at zero, since nothing is paid upfront, and adds each year's saving less twelve repayments until the loan is paid off:
Its range pairs the low saving path with the repayment on the high cost, and the reverse. The scheme caps each technology's loan (solar and batteries £15,000 each, an air-source heat pump £20,000 before the grant); an option above a cap carries a note.
What the kit may still be worth
When the customer moves, the equipment stays with the house. Because what a buyer will pay for it varies and isn't guaranteed, this is shown apart and never ranked on. Each new part's cost after grants, , is written down on a declining balance over its life (solar 12 / 20 / 25 years, batteries 7 / 10 / 12, heat pumps 10 / 15 / 20 for low / central / high), leaving a tenth at the end of its life and nothing after:
The range runs from the short lives at the end of the stay band to the long lives at its start (at least a year in).
Uncertainty ranges
Picks are made on central values only; afterwards each uncertain assumption is moved to its low and high value on its own, and the resulting moves are combined as independent errors.
| Assumption | Low / high | Affects |
|---|---|---|
| Solar, battery and heat pump installed cost | Low and high cost formulas above | Cost |
| Heat demand (space heating) | ±15% with an EPC figure or oil spend, ±30% otherwise | Saving |
| Household electricity use (excluding the car) | ±20% | Saving |
| Solar output | ±10% with Google roof data, ±15% without | Saving |
| Electricity unit rates today | ±15% | Saving |
| Heat pump efficiency (level of the temperature curve) | Reference home's SPF 2.8 / 3.9 | Saving |
| Virtual power plant payments | £120 / £300 a year | Saving |
| Future energy prices | DESNZ low and high projections | Later years |
| Panel and battery fade | 0.3–0.8% a year; 1.5–3 points a year | Later years |
For each assumption i, the change in cost or saving relative to central is measured by re-simulating the chosen options only (cost moves need no simulation, since costs are formulas). Downward and upward moves are combined separately by root-sum-square:
This gives a realistic band rather than every assumption going wrong at once. The payback range pairs low cost with high saving, and high cost with low saving.
Future prices have no spread in the install year, because today's prices are known. The low and high indices widen linearly to DESNZ's own low/central and high/central ratios by 2030 and follow those ratios afterwards:
In later years, each first-year assumption keeps its share of the central saving, while the price path and fade are worked out year by year; all are combined by root-sum-square each year.
Known limitations
The largest simplification is synthetic usage, which is deliberate for a questionnaire-only tool and is the next target for improvement. Weather is real, but from a single year.
- Weather: one real year (November 2025 to October 2026) at the nearest grid point, about 28 km apart, so results reflect that year rather than a long-term average, and a mild or harsh year moves them. Very local effects (a frost hollow, sea fog on one side of a hill) are smoothed out. The annual heating total still comes from the EPC rather than the weather.
- Heat pumps: efficiency follows the median of one supplier's fleet, scaled to our level; it does not depend on the make, the size of the radiators or the quality of the installation.
- Usage: without bills, appliance use, its daily shape and heating patterns come from typical profiles. There is no weekday/weekend difference.
- Solar geometry: shading from trees and neighbouring buildings is carried only by Google's annual sunshine hours, not by the timing through the day or year, and on the one roof checked the four darkest months came out 15 to 23% high.
- Battery control: the Level 1 planner works day by day with perfect knowledge of that day's prices and no solar forecast, so overnight charging can occasionally fill a battery before a sunny day. Level 0 assumes simple self-use. Neither is a full optimiser.
- Prices: fixed-shape tariffs repeat today's rates while Agile replays the past year, and price-cap changes appear only through the DESNZ yearly path (a 2023-vintage series, re-based). Other suppliers' export rates are priced as Outgoing Octopus unless entered by the customer.
- Physical limits: single-phase connections only (8 kW inverter maximum); no export cap is priced; no maintenance or replacement costs (such as an inverter at 10–15 years) are included.
- Uncertainty: the ranges treat assumptions as independent, and some low and high values are judgement rather than measured spread.
- Coverage: EPC lookups and grants apply to England and Wales only.
Sources
Live data and APIs
- Octopus Energy public API: products, unit rates, standing charges, Agile half-hourly prices, grid supply point by postcode
- Google Maps Platform Solar API: building insights, roof segments, sunshine hours
- Google Places API (New): address search and coordinates
- Energy Performance of Buildings data service: domestic EPCs for England and Wales
Weather
- Hersbach, H. et al. (2023), ERA5 hourly data on single levels from 1940 to present, Copernicus Climate Change Service (C3S) Climate Data Store, doi:10.24381/cds.adbb2d47: 2 m temperature and surface solar radiation (actual and clear-sky), November 2025 to October 2026. Contains modified Copernicus Climate Change Service information (2026); neither the European Commission nor ECMWF is responsible for any use of this information.
- Erbs, D.G., Klein, S.A. and Duffie, J.A. (1982), Estimation of the diffuse radiation fraction for hourly, daily and monthly-average global radiation, Solar Energy 28(4), 293–302: the diffuse share of sunshine from how clear the sky is
Prices and projections
- DESNZ, Valuation of energy use and greenhouse gas emissions for appraisal (Green Book supplementary guidance), data tables 4, 5 and 7, October 2026 edition
- DESNZ, Solar PV cost data (installed costs from MCS registrations), 2025/26 edition, May 2026
- Your NRG heating oil price index, UK average for 500 litres
- Octopus Energy export tariffs and smart tariff terms (export pairing rules, SEG rate)
- Energy Saving Trust and MoneySavingExpert 2026 solar price guides; GivEnergy and Fox ESS UK retail prices (November 2026)
Grants and tax
- Energy Saving Trust: Boiler Upgrade Scheme
- HMRC VAT Notice 708/6, energy-saving materials
Performance and ageing
- Few, J. et al. (2023), The over-prediction of energy use by EPCs in Great Britain: A comparison of EPC-modelled and metered primary energy use intensity, doi:10.1016/j.enbuild.2023.113024
- DESNZ, Energy Performance Certificate (EPC) accuracy research (May 2026)
- Energy Systems Catapult, Electrification of Heat demonstration, interim performance data
- Octopus Energy Cosy heat pump performance: fleet SPF and median COP by outdoor temperature
- NREL review of photovoltaic degradation rates (field measurements); NREL US fleet study
- RWTH Aachen field study of home battery ageing, Nature Energy (2024)
- NREL Annual Technology Baseline, residential battery storage
- Winskel, Heptonstall and Gross, UKERC heat pump cost review, Applied Energy (2024)
Other
- Axle Energy virtual power plant: guaranteed payments to battery owners
- DESNZ, Warm Homes Loan Scheme: Factsheet (October 2026) and Warm Homes Loan Scheme Rules v3 (September 2026): rate reduction, terms and loan caps
- Plan My Energy engine assumptions register